programming software - license included protective plug command devices sensors and control architecture encoder configuration modul management / device assignment easy programming (continuous function chart) network configuration wiring diagram block function monitoring functions
Freely programmable and configurable FSoE master module for operation on EtherCAT networks. convenient and easy to program using SafePLC² in FBD Library for all standard I/O elements (emergency stop, door interlock, light curtain, etc.) simple integration of safe drives (Safe Drive Profile) optionally central motion monitoring for single- or...
14 safe inputs and 3 x 2 digital semiconductor outputs no Safe Motion 14 safe digital inputs (8x OSSD tolerant) 4 High-Side outputs with 2A power 2 safe relay outputs 2 messaging outputs 2 pulse outputs (for diag purposes)dimension in mm (HxDxW): 100x115x45 ATTENTION: Required accessories (s. Fig.)
1 axis with 1 encoder 14 digital inputs 2 pulse generator outputs 2 digital outputs relay 2 digital outputs Low-Side 2 digital outputs High-Side 2 message outputs 2 pulse outputs Dimensions in mm (HxDxW): 100x115x67,5 ATTENTION: Required accessories (s. Fig.)
2 axes with 2 encoder per axis 2x2 sensor inputs for safe motion(Incremental, sin / cos, SSI absolute, initiators) and with reference interface for HTL (high definition) and resolvers 14 safe digital inputs (8 with OSSD) Secure Digital Out 2 hi-side / lo-side or hi-side 4 2 messaging outputs 2 pulse outputs (for diagnosis purpose) Dim.(HxDxW):...
without bus communication Dimensions in mm (WxHxDxW): 100x115x112,5 ATTENTION: Required accessories (s. Fig.) To connect other extension modules to the base module, 5 T-bus backplane connectors are necessary.
without bus communication Dimensions in mm (WxHxDxW): 100x115x157,5 ATTENTION: Required accessories (s. Fig.) To connect other extension modules to the base module, 7 T-bus backplane connectors are necessary.
Design of the module with the following peripherals 2 Axis4 encoder interface14 digital inputs2 pulse outputs2 relais outputs2/4 pn- oder pp-switching outputs2 auxiliary outputs1 diagnostic and configuration interface1 function button1 7-segment display1 Status-LED14 Status-LEDs for inputs2 Status-LEDs for pulse outputs2 Status-LEDs for relais outputs6...